- Same day for OderS Before 3:00 PM
- Free Delivery - Nairobi CBD
- Shipping (KENYA) & Ear Africa Countries
- Secure Shopping | Warranties
Apc Smart-Ups 750va Lcd 230v
KSh1,500,000.00 Ex.VAT
Shipping / Payment Options and Returns Policies
Payment Options | - Bank Transfer: Payments via Direct Transfer, RTGS, EFT, PesaLink, and PayPal. Invoices are issued. Order processed once payment is confirmed. |
- Mobile Payments: Accepts Mpesa via Company Paybill Numbers. | |
- Cash on Delivery (COD): Available only within Nairobi CBD; all other orders must be paid before shipment. | |
- Cash Payments: Accepted for in-store shopping. | |
Shipping | - Order Processing: Orders processed within an hour of payment confirmation; up to 3 business days subject to agreement. |
- Standard Shipping: Free within Nairobi CBD for orders over KSH 20,000. Flat rate of KSH 350 for orders below KSH 10,000. | |
- Dispatch: Orders before 15:00 dispatched same day; after 15:00 dispatched next day. Orders outside Nairobi dispatched after full payment. | |
- Delays: Delivery times may vary due to weather or carrier issues. | |
Returns and Refunds | - Eligibility: Returns accepted within 14 days; items must be unused and in original packaging. Certain items are non-returnable. |
- Initiating a Return: Contact support with order number, reason, and description. | |
- Return Shipping: Customers pay unless the item is defective. | |
- Inspection: Returns inspected for eligibility; refunds processed within 3 business days. | |
- Non-Refundable Items: Clearance items, third-party seller items, damaged items after delivery. | |
- Exchanges: No direct exchanges; follow return process and place a new order for desired items. | |
Contact Us | - Email: ke.ketexpress@gmail.com | sales@ket.co.ke |
- Phone: +254115118171 | |
- Address: Kai House, 655, Floor 4, HSE 4 Tom Mboya St | |
Notes | Shipping policy may change without notice; please review regularly for updates. |
Apc Smart-Ups 750va Lcd 230v
Scalable runtimeAllows additional run time to be quickly added as needed. Dual mains inputIncreases availability by allowing the UPS to be connected to two separate power sources. Input power factor correctionMinimizes installation costs by enabling the use of smaller generators and cabling. Hot-swappable batteriesEnsures clean, uninterrupted power to protected equipment while batteries are being replaced Manual maintenance bypassReduces installation costs by eliminating the need for an external mechanical bypass. Network manageableProvides remote power management of the UPS over the network.
APC Smart-UPS VT 20kVA ups specifications
- Output power capacity: 16.0 KWatts / 20.0 kVA
- Max Configurable Power (Watts): 16.0 KWatts / 20.0 kVA
- Nominal Output Voltage: 400V 3PH
- Output Voltage Note: Configurable for 380 : 400 or 415 V 3 Phase nominal output voltage
- Efficiency at Full Load: 95.3 %
- Output Voltage Distortion: Less than 5% at full load
- Output Frequency (sync to mains): 47 – 53 Hz for 50 Hz nominal
- Output Frequency (not synced): 50Hz +/- 0.1% for 50Hz nominal
- Other Output Voltages: 380, 415
- Load Crest Factor: 3 : 1
- Topology: Double Conversion Online
- Waveform type: Sine wave
- Maximum Output Current: 32
- Bypass: Built-in Maintenance Bypass, Built-in Static Bypass
- Nominal Input Voltage: 400V 3PH
- Input frequency: 40 – 70 Hz (auto sensing)
- Input Connections: Hard Wire 5-wire (3PH + N + G)
- Input voltage range for main operations: 304 – 477V
- Efficiency at Full Load: 95.3 %
- Other Input Voltages: 380, 415
- Maximum Input Current: 27.0A
- Input Power Factor at Full Load: 0.98
- Battery type: VRLA
- Included Battery Modules: 4
- Typical recharge time: 5hour(s)
- Nominal Battery Voltage: +/-192 V (split battery referenced to neutral)
- Expected Battery Life (years): 3 – 5
- RBC Quantity: 4
- Extendable Run Time: 1
- Interface Port(s): DB-9 RS-232 , Smart-Slot
- Pre-Installed SmartSlot™ Cards: AP9631
- Control panel: Multi-function LCD status and control console
- Audible Alarm: Audible and visible alarms prioritized by severity
- Emergency Power Off (EPO): Yes
Be the first to review “Apc Smart-Ups 750va Lcd 230v”
Apc Smart-Ups 750va Lcd 230v
Scalable runtimeAllows additional run time to be quickly added as needed. Dual mains inputIncreases availability by allowing the UPS to be connected to two separate power sources. Input power factor correctionMinimizes installation costs by enabling the use of smaller generators and cabling. Hot-swappable batteriesEnsures clean, uninterrupted power to protected equipment while batteries are being replaced Manual maintenance bypassReduces installation costs by eliminating the need for an external mechanical bypass. Network manageableProvides remote power management of the UPS over the network.
APC Smart-UPS VT 20kVA ups specifications
- Output power capacity: 16.0 KWatts / 20.0 kVA
- Max Configurable Power (Watts): 16.0 KWatts / 20.0 kVA
- Nominal Output Voltage: 400V 3PH
- Output Voltage Note: Configurable for 380 : 400 or 415 V 3 Phase nominal output voltage
- Efficiency at Full Load: 95.3 %
- Output Voltage Distortion: Less than 5% at full load
- Output Frequency (sync to mains): 47 – 53 Hz for 50 Hz nominal
- Output Frequency (not synced): 50Hz +/- 0.1% for 50Hz nominal
- Other Output Voltages: 380, 415
- Load Crest Factor: 3 : 1
- Topology: Double Conversion Online
- Waveform type: Sine wave
- Maximum Output Current: 32
- Bypass: Built-in Maintenance Bypass, Built-in Static Bypass
- Nominal Input Voltage: 400V 3PH
- Input frequency: 40 – 70 Hz (auto sensing)
- Input Connections: Hard Wire 5-wire (3PH + N + G)
- Input voltage range for main operations: 304 – 477V
- Efficiency at Full Load: 95.3 %
- Other Input Voltages: 380, 415
- Maximum Input Current: 27.0A
- Input Power Factor at Full Load: 0.98
- Battery type: VRLA
- Included Battery Modules: 4
- Typical recharge time: 5hour(s)
- Nominal Battery Voltage: +/-192 V (split battery referenced to neutral)
- Expected Battery Life (years): 3 – 5
- RBC Quantity: 4
- Extendable Run Time: 1
- Interface Port(s): DB-9 RS-232 , Smart-Slot
- Pre-Installed SmartSlot™ Cards: AP9631
- Control panel: Multi-function LCD status and control console
- Audible Alarm: Audible and visible alarms prioritized by severity
- Emergency Power Off (EPO): Yes
Reviews
There are no reviews yet.
Reviews
There are no reviews yet.